HiVis
Category: Falls

Fall Protection Basics

When fall protection is required, how to check a harness, and why the anchor matters as much as the lanyard.

Versión en español

Why it matters

In construction, fall protection is required at 6 feet. A harness only works if it fits, is inspected and is tied to an anchor that can hold the load.

Key points

  • Guardrails, safety nets or personal fall arrest are required at 6 feet in construction.
  • Inspect the harness before use: webbing, stitching, D-ring and buckles.
  • Adjust the harness snug: you should fit only a flat hand under the leg straps.
  • Anchor points must be rated for 5,000 lb per worker or designed by a qualified person.
  • Plan the rescue before work starts. Suspension trauma can begin within minutes.
  • Cover and mark every floor hole and skylight.

Discussion questions

  1. Where are today's fall hazards and what is our protection for each?
  2. Who checked the anchors and harnesses this morning?
  3. If someone falls and is hanging in a harness, what is our rescue plan?

Reference: OSHA 29 CFR 1926.501

Related