Why it matters
In construction, fall protection is required at 6 feet. A harness only works if it fits, is inspected and is tied to an anchor that can hold the load.
Key points
- Guardrails, safety nets or personal fall arrest are required at 6 feet in construction.
- Inspect the harness before use: webbing, stitching, D-ring and buckles.
- Adjust the harness snug: you should fit only a flat hand under the leg straps.
- Anchor points must be rated for 5,000 lb per worker or designed by a qualified person.
- Plan the rescue before work starts. Suspension trauma can begin within minutes.
- Cover and mark every floor hole and skylight.
Discussion questions
- Where are today's fall hazards and what is our protection for each?
- Who checked the anchors and harnesses this morning?
- If someone falls and is hanging in a harness, what is our rescue plan?
Reference: OSHA 29 CFR 1926.501